1Program Studi Sistem Komputer, Fakultas Teknik, Universitas Diponegoro, Indonesia
2Program Studi Sistem Komputer, Universitas Diponegoro, Indonesia
BibTex Citation Data :
@article{JTSISKOM2538, author = {Anggit Perdana and Adian Fatchur Rochim and Eko Didik Widianto}, title = {Purwarupa Sistem Pemantau dan Peringatan Kadar Gas Karbon Monoksida (CO) pada Kabin Mobil Berbasis Mikrokontroler ATMega8}, journal = {Jurnal Teknologi dan Sistem Komputer}, volume = {1}, number = {2}, year = {2013}, keywords = {Carbon monoxide gas detector;Gas censor TGS 2442;LCD;Buzzer;Vibrating motor}, abstract = {High growth in vehicle, contribute air pollution and reduce human health quality. One of pollutants that generated by motor vehicle emissions is carbon monoxide (CO). CO gas can cause health problems for humans, even if exposed to long periods time will cause death. Emission test devices have been widely available in many auto repair shops, but at the moment emission testing, only read gas source or emissions sources from the muffler hole. Cabin space usually escaped from checking, whether there is pollution that enters the cabin or not. This final project has a purpose to design a carbon monoxide detector devices which will show the levels of carbon monoxide (CO) into 4 categories of air quality,that are safe, wary, watch out, and danger. System will automatically warning the driver if the gas exceeds the threshold. Microcontroller that used as the central data processing data is microcontroller Atmega 8, by ATMEL and use gas censor TGS 2442. Design begin with a hardware schematic and software design using BASCOM-AVR. Implementation phase include the implementation of the physical device, programs, and censor. Testing phase is done by testing the tool using 3 gas source, that are cigarette smoke, motorcycle exhaust, and car exhaust. The test result showed that the highest error rate on these tool when compared with a comparable gas analyzer scott instruments is 6.46%, with 93.54% accuracy rate. This CO gas monitor hasadvantage easily portable and include three actuators, that are LCD will show the levels of CO gas, buzzer will give warning sound when gas exceeds the threshold, and the vibrating motor provide tactile warning to the user.}, issn = {2338-0403}, pages = {34--41} doi = {10.14710/jtsiskom.1.2.2013.34-41}, url = {https://jtsiskom.undip.ac.id/article/view/2538} }
Refworks Citation Data :
Article Metrics:
Last update:
Last update: 2024-11-21 11:14:45
Starting from 2021, the author(s) whose article is published in the JTSiskom journal attain the copyright for their article and grant the journal right of first publication with the work simultaneously licensed under a Creative Commons Attribution-ShareAlike 4.0 International License. By submitting the manuscript to JTSiskom, the author(s) agree with this policy. No special document approval is required.
The author(s) guarantee that:
The author(s) retain all rights to the published work, such as (but not limited to) the following rights:
Suppose the article was prepared jointly by more than one author. Each author submitting the manuscript warrants that all co-authors have given their permission to agree to copyright and license notices (agreements) on their behalf and notify co-authors of the terms of this policy. JTSiskom will not be held responsible for anything arising because of the writer's internal dispute. JTSiskom will only communicate with correspondence authors.
Authors should also understand that their articles (and any additional files, including data sets and analysis/computation data) will become publicly available once published. The license of published articles (and additional data) will be governed by a Creative Commons Attribution-ShareAlike 4.0 International License. JTSiskom allows users to copy, distribute, display and perform work under license. Users need to attribute the author(s) and JTSiskom to distribute works in journals and other publication media. Unless otherwise stated, the author(s) is a public entity as soon as the article is published.